Replacement double-glazed and triple-glazed units, made to measure for UK retrofit. Configure your unit below: choose glass type, cavity width, gas fill (argon or krypton), performance options (low-E, acoustic, safety), and frame compatibility. Get an instant price, save your configuration, and order online. Standard double-glazed units are made and dispatched in 5–7 working days.

Every unit is manufactured to BS EN 1279 and made for us by a partner factory. If you're not sure of the spec, our glass calculator recommends one based on your window's current performance and the room it sits in.

Door Glass Units — UK Standards, Specifications, and Replacement Glazing for Front, Patio, French, and Bi-Fold Doors

Door glass is the most safety-critical glazing in a typical UK building. Every glazed door panel sits in a "critical location" under Approved Document K, which means the glass must carry an impact classification — toughened, laminated, or toughened-laminated to BS EN 12150, BS EN 14449 or BS EN 14179. This page covers the standards that govern door glazing, the typical specifications for composite front doors, French doors, patio sliders and bi-folds, and how to choose between toughened and laminated for each opening type.

Specification predicates buyers compare on

The attributes below are the buyer-intent predicates we see most often in door-glass enquiries, FENSA replacement orders, and trade specifications. Use them to compare like-for-like across suppliers and to brief Building Control on what you intend to install.

Predicate Typical range Where it matters
Impact classification (BS EN 12600) 1(C)1 toughened, 1(B)1 laminated Mandatory for every glazed door panel (Approved Document K Section 6)
Toughening standard BS EN 12150-1 (standard); BS EN 14179 (heat-soaked) Heat-soak reduces nickel sulphide fracture risk on high-value doors
Lamination standard BS EN 14449; PVB 0.38 mm – 1.52 mm Required for overhead glazing; recommended for security-rated doors
Composite door insert IGU thickness Typical 24 mm sealed unit, 4–14–4 or 4–16–4 low-E + argon Standard composite door slab cassette — verify slab manufacturer's groove depth
French / patio door pane size 500–800 mm × 1800–2100 mm typical leaf glazing Toughened 4 mm sufficient below 800 mm width; 6 mm above
Bi-fold door pane size 800–1000 mm × 2000–2400 mm per leaf Toughened-laminated common for large bi-folds (residual barrier on fall risk)
U-value (sealed unit) 1.2 – 1.4 W/m²K (low-E coated, argon, warm-edge) Building Regs Part L; FENSA replacement compliance
Acoustic rating Rw 30 – 42 dB depending on build-up Front doors on busy roads; patio doors near garden traffic
Letterbox cutout (composite / timber doors) 250–280 mm × 40–70 mm aperture, ≥400 mm from lock Approved Document Q for new dwellings; TS 008 retrofit guidance
Edge treatment Ground arrissed; polished for visible-edge bi-folds Required on toughened for clean cut; polished improves perceived quality
Critical-location threshold 1500 mm from finished floor level Approved Document K Section 6 — applies to every door pane and side panel

Door glazing by opening type

Front-door composite replacement

The most common door-glass enquiry Pane Relief handles is a cracked decorative pane in a composite front door. Composite doors (GRP skin, foam core, timber subframe) are supplied with a pre-machined slab and a cassette glazing system that accepts a sealed unit of a defined thickness — almost universally 24 mm for UK composite doors, though some premium slabs use 28 mm or 44 mm triple-glazed cassettes. The IGU is normally a 4–16–4 toughened-low-E-argon sealed unit with a decorative interlayer. Both panes must be impact-classified because Approved Document K does not distinguish between inner and outer face in a critical location.

When replacing, capture from the customer: (1) cassette thickness measured edge-to-edge; (2) sight-size width × height (visible glass area, not aperture cutout); (3) decorative pattern and obscure level (1–5 BS scale); (4) any directional features (bevels, leaded designs) with a "right way up"; (5) the door slab manufacturer if known, because some slab profiles have proprietary cassette grooves. The glass calculator walks customers through this; the door-glass-units collection lists the most-ordered cassette sizes.

Patio sliding doors and French doors

Patio (sliding) and French (hinged, double-leaf) doors have different failure modes. Sliding patio doors carry glass weight on a bottom roller and bumper; the spec must leave adequate edge cover (typically 12 mm minimum) so the gasket seats without point-loading the toughened edge. Toughened 4 mm sealed units (4–16–4 or 4–20–4) cover most domestic patio leaves up to about 1100 mm × 2100 mm; above that, 6 mm toughened manages deflection and wind load. French door leaves are typically narrower (500–800 mm), so 4 mm toughened remains adequate, but the leaf height (up to 2100 mm) is a heavy unit on a single hinge stack — hinge rating matters as much as glass thickness.

For acoustic-sensitive patio installations, an acoustic-laminated build-up — 6.4 mm acoustic-PVB laminated outer + 4 mm toughened inner — delivers Rw 36–38 dB versus 30 dB for a standard toughened 4–16–4. See acoustic glass for Rw vs build-up data.

Bi-fold doors and commercial-opening glazing

Bi-fold door leaves are typically the largest single-pane glazing in a domestic specification — 800–1000 mm wide × up to 2400 mm tall. Two issues emerge at that scale. First, fall-from-height: a tall pane over a low cill can act as a falling-impact barrier, so BS 6180 requires the glass to retain barrier function after fracture — pushing the spec toward toughened-laminated rather than toughened alone. Second, thermal stress: large south-facing panes pick up solar gain on the unshaded half, and that thermal differential is a known nickel-sulphide fracture trigger — making heat-soaked toughened to BS EN 14179 the right choice for premium bi-folds.

Commercial bi-fold openings (cafés, hospitality, school halls) add: BS 6262-4 manifestation markers at 850–1000 mm and 1400–1600 mm, the Equality Act 2010 walking-into-glass obligation, and on public-facing installs a P1A or P2A security-rated outer pane to deter casual vandalism. See safety and security glass.

Toughened vs laminated vs toughened-laminated — for door glass

For door glazing specifically, three options dominate the spec sheet: toughened, laminated, and toughened-laminated. The choice is rarely between toughened and laminated in absolute terms — it is about which failure mode you want at the specific door location.

Type Classification Failure mode When to specify for doors
Toughened BS EN 12150-1; 1(C)1 Granular pieces; no residual barrier Default for composite front-door cassettes, French door leaves under 1.8 m, internal half-glazed doors
Heat-soaked toughened BS EN 14179; 1(C)1 Granular; reduced nickel-sulphide risk Premium bi-folds, south-facing large panes, hard-to-access overhead door glazing
Laminated BS EN 14449; 1(B)1 Cracks but held by PVB interlayer; residual barrier Overhead door glazing, listed-property door restorations, PAS 24 attack face
Toughened-laminated BS EN 12150 + 14449; 1(B)1 Granular fracture + PVB retention Large bi-folds where both fall-protection AND blunt failure required; commercial high-traffic doors

The critical-location rule (Approved Document K, 1500 mm from FFL) means none of these is "more compliant" than the others — all four meet the impact classification. The decision is driven by the secondary risk: do you need a residual barrier after fracture (laminated or toughened-laminated)? Or is granular blunt failure acceptable and cost-down the priority (toughened)? For a typical composite front door at street level, toughened is correct and adequate. For an upstairs Juliet bi-fold over a balcony, laminated or toughened-laminated is correct.

Standards bodies and regulatory references

This page references the following UK standards bodies, regulators, and trade associations. Their published documents are the authoritative source for any door-glazing specification decision.

  • Approved Document K — Protection from falling, collision and impact — the primary statutory reference for door-glass impact safety in England. Section 6 defines the critical-location envelope (1500 mm from FFL, 300 mm from a door edge).
  • BSI Group — publisher of BS EN 12150 (toughened), BS EN 14449 (laminated), BS EN 14179 (heat-soaked toughened), BS EN 12600 (impact classification), and the legacy BS 6206 classification. Available individually or via BSI Knowledge subscription.
  • FENSA — Fenestration Self-Assessment Scheme. Installation by a FENSA-registered firm self-certifies compliance with Approved Documents K and L for replacement door and window glazing in dwellings. Pane Relief supplies through FENSA-registered installers.
  • British Board of Agrément (BBA) — third-party certification for proprietary door systems and PAS 24 frame-glass-locking assemblies. BBA-certified composite door slabs include the IGU cassette compatibility in their certificate.
  • Glass and Glazing Federation (GGF) — UK trade body. The GGF Glazing Manual is the working reference for door-glass thickness selection, edge cover, and gasket specification.
  • Planning Portal — consolidated guidance on Approved Document Q (Security in dwellings — letterbox restrictions, PAS 24 requirements) and the equivalent technical standards for Wales, Scotland, and Northern Ireland.

Frequently asked questions about door glass units

What glass do I need for my front door?
Every glazed front-door panel sits in a "critical location" under Approved Document K Section 6 (within 1500 mm of finished floor level), so the glass must be impact-classified — either toughened to BS EN 12150 (1(C)1) or laminated to BS EN 14449 (1(B)1). For a typical composite front door at street level, toughened is the default and adequate. If the door is a Listed Building, overhead, or part of a PAS 24 security-certified assembly, laminated is required instead.
Is toughened glass enough for a door, or do I need laminated?
Toughened glass alone meets Approved Document K for almost all domestic door applications. Laminated is required only where (a) there is a fall risk behind the door (e.g., a Juliet balcony glazed door), (b) the door is overhead glazing, (c) the door is part of a PAS 24-certified security assembly in a new dwelling, or (d) the project specifies post-fracture residual barrier for any reason. For composite front doors, internal half-glazed doors, and standard French / patio leaves, toughened is correct.
Do I need laminated glass for a glazed door in a PAS 24 assembly?
In practice, yes. PAS 24:2022 tests the complete door — frame + glazing + locking — against a forced-entry sequence. The glazing on the attack face must resist a 50 mm hammer / chisel attack for 3 minutes. Toughened glass alone, while impact-classified for safety, does not pass the PAS 24 attack sequence because once it shatters the assembly is open. A laminated inner pane (with PVB or SGP interlayer) holds the fragments together and forces the attacker to defeat the locking instead.
What is the typical spec for a composite door insert?
UK composite doors (GRP-skinned, foam-cored, timber-subframed) almost universally use a 24 mm sealed-unit cassette: a 4–16–4 or 4–14–4 toughened-low-E-argon IGU with a decorative interlayer. Both panes must be impact-classified. Some premium slab manufacturers use 28 mm cassettes (e.g., higher U-value low-E builds) or 44 mm triple-glazed cassettes — always verify the cassette thickness from the slab manufacturer before ordering replacement glass. The glass calculator captures the spec step-by-step.
What is nickel sulphide fracture and should I worry about it for door glass?
Nickel sulphide (NiS) is a microscopic impurity occasionally present in float glass. When the glass is thermally toughened, NiS inclusions can change phase over time and expand slightly — and if a large enough inclusion sits near the centre of a toughened pane in tension, it can trigger a spontaneous fracture, sometimes years after installation, without any external impact. The risk is low (industry estimates around 1 in 10,000 panes) but real. Heat-soaking the glass after toughening (BS EN 14179) heats it to 290°C for 2 hours, causing any unstable NiS inclusions to fail in the factory rather than the finished installation. For premium bi-folds, large south-facing patio leaves, and hard-to-access overhead door glazing, heat-soaked toughened is the right specification.
Do French doors need different glass to my windows?
The glass type required (toughened or laminated) is the same — Approved Document K applies. What changes is the build-up. French door leaves are narrower (typically 500–800 mm) and taller (1800–2100 mm) than a standard window, with most of the leaf inside the critical-location envelope. 4 mm toughened sealed units cover leaves under 800 mm wide; above that, step up to 6 mm to manage deflection and wind load. Hinge specification matters more than for windows because each leaf is a heavy long lever. See the door-glass-units collection for stock sizes.
What are the letterbox cutout rules for a glazed front door?
For new dwellings, Approved Document Q (Security in dwellings, Section 6.6) requires the letterbox plate to restrict reach-through access. In practice this means: (1) the cutout sits at least 400 mm from any thumb-turn lock; (2) the plate is fitted with an internal restrictor cowl that prevents an arm fishing for the latch; (3) the letterbox is itself a tested unit, typically to TS 008. The cutout sits in the door slab, not the glass — but if your composite door has a side-glazed light close to the letterbox, the same 400 mm reach-through rule applies to the glass area too. Specify the slab cutout location at order, not after delivery.
What thickness of safety glass do I need for a patio door?
For a domestic sliding patio leaf up to about 1100 mm × 2100 mm, 4 mm toughened in a 4–16–4 or 4–20–4 sealed unit is standard and meets BS EN 12600 1(C)1. Above 1100 mm leaf width or 2200 mm leaf height, step up to 6 mm toughened to manage deflection and wind load — typically a 6–18–4 or 6–20–6 build-up. For acoustic-sensitive locations, swap the outer pane for 6.4 mm acoustic-PVB laminated to gain Rw 36–38 dB. The glass calculator recommends a thickness based on leaf size and acoustic requirement.
Can I buy a single door-glass unit, or do I need to order both panes?
A door-glass unit is a sealed insulated glazing unit (IGU) — two panes of glass bonded around a spacer bar with a desiccant-filled cavity. It is supplied as a single sealed cassette; you cannot replace just one pane without breaking the seal and losing the cavity gas. Pane Relief supplies replacement door cassettes made to size, with both panes impact-classified, a warm-edge spacer bar as standard, and argon fill available as an upgrade. Order via the door-glass-units collection for stock sizes or the door configurator for bespoke.
FENSA Registered BS EN 1279 Certified 10-Year Guarantee